<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-03 07-16-03
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 73 dBuV YLEX
Pilot RDS Phase Difference
6.1 kHz 3.2 kHz 76 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 60 kHz 14617 0,5063
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,6 dBr 2,27 dBr 4,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 7:16, 3.07.2025
RT
"JVG, EMMA & MATILDA - Kävi miten kävi when you're high "
AF EON
87.6 MHz 6207, 6903, 6205, 6201
FM Scope Max at: 60 kHz MIN: 9 kHz % above 76 kHz: 0,5063 Acquired: 2025/07/03 7.15.00 Total samples: 14617 Equivalent time: 0:12:10 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600